How to Install Snmp Service on Promxox VE

How to install snmp service on proxmox ve How to setup snmp service to let us to use librenms to moniting our proxmox ve healthy status is very important for us. Install snmpd on proxmox ve apt update apt install -y snmpd Configure snmpd.conf backup original configuration file. mv /etc/snmp/snmpd.conf /etc/snmp/snmpd.conf.backup Create a new config file. cat > /etc/snmp/snmpd.conf << EOF # this create a SNMPv1/SNMPv2c community named "" # and restricts access to LAN adresses 192.

DIY Thin Itx PC

Option 1 :Intel Pentium G4560/8G RAM/ 1TB nvme ssd No. type details quantity UnitPrice Total Price 01 机箱 立人E-T4超薄迷你Thin-ITX立式台式机HTPC电脑空机箱支持VESA背挂 1 ¥90(90.00*

Proxmox Ve How to Chang Network of Hosting Without Reboot Proxmox Ve

How to change Network settings of proxmox-ve host without rebooting. Eache time when I want to change network settings like change netowrks and I must reboot to apply it. It is really trouble me. Solution Proxmox VE is based on debian. After check interface of network with the path /etc/network/ I found that each time when i change network settings. There will be a named interfaces.new created and it content new network settings wait for apply when i reboot.

Proxmox VE - How to Convert Vmware Esxi VM to proxmox-VE VM

How to convert vmware esix VM to proxmox-VE VM V2V Convert vmware virtual machines to kvm virtual machine is easy. Convert windows VM Remove VWware tools Uninstall vmware tools and reboot vm. Switch disk mode to IDE Download Mergeide, unzip it and run it,then reboot your vm. or you can save follow code as mergeide.reg. Windows Registry Editor Version 5.00 [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\primary_ide_channel] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="atapi" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\secondary_ide_channel] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="atapi" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\*pnp0600] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="atapi" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\*azt0502] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="atapi" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\gendisk] "ClassGUID"="{4D36E967-E325-11CE-BFC1-08002BE10318}" "Service"="disk" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#cc_0101] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_0e11&dev_ae33] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1039&dev_0601] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1039&dev_5513] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1042&dev_1000] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_105a&dev_4d33] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1095&dev_0640] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1095&dev_0646] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1095&dev_0646&REV_05] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1095&dev_0646&REV_07] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1095&dev_0648] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1095&dev_0649] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1097&dev_0038] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_10ad&dev_0001] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_10ad&dev_0150] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_10b9&dev_5215] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_10b9&dev_5219] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_10b9&dev_5229] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="pciide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_1106&dev_0571] "Service"="pciide" "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_1222] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="intelide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_1230] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="intelide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2411] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="intelide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_2421] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="intelide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_7010] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="intelide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_7111] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="intelide" [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\CriticalDeviceDatabase\pci#ven_8086&dev_7199] "ClassGUID"="{4D36E96A-E325-11CE-BFC1-08002BE10318}" "Service"="intelide" ;Add driver for Atapi (requires Atapi.

Vyos How to Setup Wireguard

How to conifugre wireguard in vyos WireGuard is an extremely simple yet fast and modern VPN that utilizes state-of-the-art cryptography. Wireguard Today I will try to deploy wireguard with two vyos . Site-to-Sit mode Toplogy |--------------------------------| |---------------------------------| | Server | | Client | | |-----cloud ----| wan:${wan-address} | | wireguard tunnel interface:wg01| | Wireguard tunnel interface:wg01 | |--------------------------------| |---------------------------------| Server configuration # Generates a new keypair, if one exists already is asks you if you want to overwrite the existing one.

Librenms Deploy Librenms With Docker Container

How to deploy librenms monitoring system with docker container Librenms is a very light and easy handle moniting software. It is suitable for us to monitoring server,networdevice, printer etc via snmp. At now, docker is easy for software deployment. After deploy librenms in ubuntu vm, I have a try to deploy librenms with docker-compose. Install librenms with docker-compose mkdir -p librenms-docker-compose cd ./librenms-docker-compose wget https://raw.githubusercontent.com/librenms/docker/master/examples/compose/.env wget https://raw.githubusercontent.com/librenms/docker/master/examples/compose/docker-compose.yml wget https://raw.githubusercontent.com/librenms/docker/master/examples/compose/librenms.env touch acme.

Proxmov Ve How to Upgrade Pve

How to ugrade Proxmove VE If your proxmox ve server in china ,Change utsc mirrors will speed up your proxmoxve upgrade speed. Here are the steps. 1. Change debian,pve,ceph upgrade source, and upgrade your PVE #chang debian source list echo "deb https://mirrors.ustc.edu.cn/debian/ stretch main contrib non-free deb-src https://mirrors.ustc.edu.cn/debian/ stretch main contrib non-free deb https://mirrors.ustc.edu.cn/debian/ stretch-updates main contrib non-free deb-src https://mirrors.ustc.edu.cn/debian/ stretch-updates main contrib non-free deb https://mirrors.ustc.edu.cn/debian/ stretch-backports main contrib non-free deb-src https://mirrors.

How to Build a Kms Server

How to build a kms server Option 1: docker mode docker pull luodaoyi/kms-server docker run -itd -p 1688:1688 --name kms luodaoyi/kms-server docker update --restart=always $dockername Option 2: docker compose docker-compose.yml version:'3'services:frontend:image:luodaoyi/kms-servercontainer_name:mykmsports:- 1688:1688restart:alwaysdocker-compose start the container docker-compose up -d Active Script echo "To active office" cd "%programfiles%\Microsoft Office\Office16" cscript ospp.vbs /sethst:xx.xx.xx.xx cscript ospp.vbs /act echo "to active windows" slmgr /skms xxx.xxx.xxx.xxx slmgr /ato Reference blog

How to Setup Oh My Zsh

How to setup Oh-My-Zsh Install support application apt install git curl wget zsh Install zsh via curl sh -c "$(curl -fsSL https://raw.githubusercontent.com/robbyrussell/oh-my-zsh/master/tools/install.sh)" via wget sh -c "$(wget https://raw.githubusercontent.com/robbyrussell/oh-my-zsh/master/tools/install.sh -O -)" Change zsh settings change theme #change theme froy robbyrussell to agnoster sed -i 's/ZSH_THEME=\"robbyrussell\"/ZSH_THEME=\"agnoster\"/g' ~/.zshrc change plugin support sed -i 's/plugins=(git)/plugin=(\n\tgit\n\tboundler\n\tdotenv\n\trake\n\trbenv\n\truby\n\tpython\n)/g' ~/.zshrc Switch default bash to zsh chsh -s /bin/zsh

How to Setup Vim

How to setup vim Install vundle vundle is a plugin manage tools for vim git clone https://github.com/VundleVim/Vundle.vim.git ~/.vim/bundle/Vundle.vim Edit vim configure file cat > ~/.vimrc <<EOF set nocompatible " be iMproved, required filetype off " required syntax on " set the runtime path to include Vundle and initialize set rtp+=~/.vim/bundle/Vundle.vim call vundle#begin() " alternatively, pass a path where Vundle should install plugins "call vundle#begin('~/some/path/here') " let Vundle manage Vundle, required

How to Enable Docker in Lxc

How to install docker-ce in lxc container in pve At now, Proxmox is base debian and it can be install docker directly. To install docker in host without proxmox support. It will be lost HA function. Deploy a vm then install docker-ce in the vm, it works. but take a lot resource than directly install docker in proxmox. Is there a way to take less performance ,at the same time

How to Enable Proxmoxve Nested Virtualization

How to enable Proxmox VE nested virtualization To enable nested virtualization on Proxmox VE, we need to stop all the vm and enable nested virtualization to linux kernel. then change vm settings Stop all the vm on proxmox VE stop all virtual machines with shell command. root@xa-sys-pve01:~# pvesh create /nodes/localhost/stopall Stopping VM 116 (timeout = 180 seconds) Stopping VM 115 (timeout = 180 seconds) Stopping CT 112 (timeout = 60 seconds) Stopping CT 111 (timeout = 60 seconds) Stopping CT 108 (timeout = 60 seconds) Stopping CT 106 (timeout = 60 seconds) Stopping VM 101 (timeout = 180 seconds) UPID:xa-sys-pve01:0036EA66:01992199:5CB98D6C:stopall::root@pam: stop all the virtual machine with admin web.

How to Extend Lvm Allocted PE With Freee PE

LVM EXTEND How to extend lvm size use free PE # show volume group information vgdisplay --- Volume group --- VG Name ubuntu-vg System ID Format lvm2 Metadata Areas 1 Metadata Sequence No 2 VG Access read/write VG Status resizable MAX LV 0 Cur LV 1 Open LV 1 Max PV 0 Cur PV 1 Act PV 1 VG Size <99.00 GiB PE Size 4.00 MiB Total PE 25343 Alloc PE / Size 1024 / 4.